Floating Floor for a Testing Room at the VW Plant, Córdoba / Argentina
Project Floating Floor for a Testing Room at the VW Plant, Córdoba / Argentina |
Design Load 1400 kN |
Vibration Source Neighbouring street traffic as well as internal plant traffic |
Vertical system natural frequency 3 Hz |
Technical Data Area: 192 qm Floating Floor Thickness: 0.3 m |
Base Isolation system 63 Floating Floor - spring elements, Typ P4F |
Execution 2001 |