          Residential and Office Building - Brunnenstr. / Ramlerstr. - Berlin / Germany



          Brunnenstr. / Ramlerstr., Berlin / Germany
          Levelling of the spring elements with shims
          Protection of spring elements against dirt
          Brunnenstr. / Ramlerstr., Berlin / Germany
          Project
          Brunnenstr. / Ramlerstr., Berlin / Germany
          Design load
          51.550 kN
             
          Building
          Two 5-story residential buildings with shops
          Arrangement of spring elements
          Below the building
             
          Structure
          Reinforced concrete
          Vibration control effect
          85-90%
             
          Noise and Vibration source
          Underground line. Main frequency 20 - 25 Hz.
          Vibration levels increased because of resonance in the air-raid shelter top deck
          Completion
          1986
             
          Special problems
          Foundation on (2) levels. Part of the foundation is sitting on top of an old air-raid shelter.
          Developer
          GAW, Berlin
             
          Base isolation system
          Fully-prestressable GERB spring units, Type GP + GPV
          Vertical natural system frequency 4,0 Hz
           